Avatar
Hello everyone, apologies if this has been addressed before, but I am currently designing a power converter and have a couple of questions regarding current limits: 1. What is the maximum current-carrying capacity (or electromigration limit) that the power pads can handle? 2. What is the maximum current (fusing current) that the bonding wires can support? Any documentation or reference values would be greatly appreciated. Thanks in advance!
Avatar
For (1) there are electromigration limit listed in the PDK doc, you can just apply those to the layout of the pad and estimate it your self.
6:40 p.m.
For (2) the wire used for this run was AlSi1% 1mil
Avatar
Avatar
tnt
For (2) the wire used for this run was AlSi1% 1mil
Tim 'mithro' Ansell 2026-06-06 6:54 a.m.
I believe it's actually 0.8mil?
👍 1
Avatar
@Tim 'mithro' Ansell Ah maybe ... looking back at the pics you took one says 1 mil the other 0.8 😅
Avatar
Tim 'mithro' Ansell 2026-06-06 7:00 a.m.
I think they normally use 1mil but needed to use 0.8mil for our parts.
Avatar
Avatar
Tim 'mithro' Ansell
I think they normally use 1mil but needed to use 0.8mil for our parts.
Yeah you said that and that it's like 5x or something the cost (for the Al wire)